AHH is Mollier HX Diagram and Carrier XH Diagram for air humid. Calculate all air technical processes. We offer climate, comfort and control areas to facilitate the planning of complex systems. Interfaces for global meteorological data and office applications are available.
The configurator for air-handling units shows approximate values for the weight, the pressure drop and the price. With "Drag and drop", the individual components can be selected. You obtain all essential data for the air-handling unit in few minutes.
Download AHU1
30 days free trial, version 14.5.1, size 11 MB
Web demo-version of AHU1 is available on : http://zcswebapps.com/AHU/AHU1.html
Prepare meteorological data (8760 hours) and service time; interface to the Mollier HX diagram and diverse HVAC software, like АНН, DEH и ESH.
Determination of the annual energy needs, operating costs, capital costs, payback period and CO2-saving for air conditioning units with heating and cooling recovery.
Heating of air humid with liquid agents. All diverse geometries are supported now.
Download Heater
30-day free trial, version 14.10.1, size 11 MB
Cooling of air humid with liquid agents. All diverse geometries are supported now.
Download Cooler
30-day free trial, version 14.10.1, size 11 MB
Heating of air humid with refrigerants or steam. All diverse geometries are supported now.
Download Condenser программу Condenser
30-day free trial, version 14.10.1, size 11 MB
Cooling of air humid with refrigerants. All diverse geometries are supported now.
Download DXEvaporator
30-day free trial, version 14.10.1, size 11 MB
Cooling of air humid with refrigerants. All diverse geometries are supported now.
Download RCEvaporator
30-day free trial, version 14.10.1, size 11 MB
CC-System: Evaluation of the yearly energy savings and the amortization time.
Download CCSA
30-day free trial, version 14.10.1, size 11 MB
CC-System: Evaluation for winter and summer (1 fin coil heat exchanger each in the supply air and exhaust air). All diverse geometries are supported now.
Download CCSB
30-day free trial, version 14.10.1, size 11 MB
CC-System: Evaluation for winter, transition, summer and sultriness (1 fin coil heat exchanger each in the supply air and exhaust air and 1 or 2 plate heat exchanger in the agent circuit). All geometries are supported.
Download CCSD
30-day free trial, version 14.10.1, size 11 MB
CC-System: Evaluation for summer and winter. All geometries are supported. CCSF is the optimal dehumidifying coupling for the summer because you can reach arbitrarily small values of humidity.